YD04012

YD04012

Features 

Mixed power power line, signal line, Ethernet, USB, industrial bus, control line, solenoid valve, induction line, etc.
Standard flange installation form, can be customized hollow shaft installation;
The medium that can pass through are: compressed air, hydrogen, nitrogen, chemical mixture gas, steam, cooling water, hot water, hot oil, petroleum, sulfuric acid, beverage, etc.
 

Order model description

YD04012(4 in 4 out,10~12mm trachea,Pure pneumatic rotary joint)Size chart

List of Standard Models

 

Model Number of the trachea Interface size Adaptive trachea
YD04012 4 in 4 out  G3/8" 10~12mm

 

 

YD04012(4 in 4 out,10~12mm trachea)+6~36 road signal/2A(Adapts to battery valves and induction switches)

List of Standard Models

Model Number of the trachea Interface size Adaptive trachea Signal approach Length(mm)
YD04012-06 4 in 4 out  G3/8" 10~12mm 6 14
YD04012-12 4 in 4 out  G3/8" 10~12mm 12 21
YD04012-24s 4 in 4 out  G3/8" 10~12mm 24 35
YD04012-36s 4 in 4 out  G3/8" 10~12mm 36 52.3
YD04012-56S 4 in 4 out  G3/8" 10~12mm 56 82

 

YD04012(4 in 4 out,10~12mm trachea)+Signal(5A)/10A

List of Standard Models

Model Number of the trachea Interface size Adaptive trachea  Electricity(10A) road number Signal(5A) Length(mm)
YD04012-0605 4 in 4 out  G3/8" 10~12mm 0 6 48
YD04012-0610 4 in 4 out  G3/8" 10~12mm 6 0 48
YD04012-1205 4 in 4 out  G3/8" 10~12mm 0 12 72
YD04012-0610-0605 4 in 4 out  G3/8" 10~12mm 6 6 72
YD04012-1210 4 in 4 out G3/8" 10~12mm 12 0 72
YD04012-0610-1205 4 in 4 out  G3/8" 10~12mm 6 12 96
YD04012-1210-0605 4 in 4 out G3/8" 10~12mm 12 6 96
YD04012-1805 4 in 4 out G3/8" 10~12mm 0 18 96
YD04012-1810 4 in 4 out G3/8" 10~12mm 18 0 96
YD04012-0610-1805 4 in 4 out  G3/8" 10~12mm 6 18 120
YD04012-2405 4 in 4 out  G3/8" 10~12mm 0 24 120
YD04012-2410 4 in 4 out G3/8" 10~12mm 24 0 120
YD04012-3605 4 in 4 out G3/8" 10~12mm 0 36 168
YD04012-1210-2405 4 in 4 out G3/8" 10~12mm 12 24 168
YD04012-3610 4 in 4 out G3/8" 10~12mm 36 0 168
YD04012-4805 4 in 4 out G3/8" 10~12mm 0 48 216
YD04012-1210-4805 4 in 4 out G3/8" 10~12mm 12 36 216
YD04012-4810 4 in 4 out G3/8" 10~12mm 48 0 216
YD04012-6005 4 in 4 out G3/8" 10~12mm 0 60 264
YD04012-1210-4805 4 in 4 out G3/8" 10~12mm 12 48 264
YD04012-7205 4 in 4 out G3/8" 10~12mm 0 72 312
YD04012-2410-4805 4 in 4 out G3/8" 10~12mm 24 48 312
YD04012-8405 4 in 4 out G3/8" 10~12mm 0 84 360
YD04012-2410-6005 4 in 4 out G3/8" 10~12mm 20 60 360
YD04012-9605 4 in 4 out  G3/8" 10~12mm 0 90 408
YD04012-10805 4 in 4 out G3/8" 10~12mm 0 108 456
YD04012-12005 4 in 4 out  G3/8" 10~12mm 0 120 504


Technical parameters

Number of the trachea 4 in 4 out Maximum pressure Positive pressure:1Mpa,vacuo:-100kpa
Number of the trachea 10~12mm trachea G3/8 tooth Torque <0.4N.m
  Mechanical Technique Indicators   Electrical Technique Indicators
Parameter Numerical Parameter Numerical
Working life 20 million turn    Power        Signal
Highest speed Continuous rotation 250/ min, intermittent rotation 1000/min Nomina Voltage 0-440VAC/VDC 0-440VAC/VDC
Working  temperature -30℃~80℃ Insulation resistance <500MΩ/300VDC <500MΩ/300VDC
Working humidity 0-85%RH Wire specifications AWG26#Silver-plated Teflon AWG26#Silver-plated Teflon
Contact materials Precious metal contact Wire length Standard length 250mm (can be adjusted according to requirements)
Case material Aluminum alloy Dielectric strength 500VAC@50Hz,6s
Protection grade IP51 Dynamic resistance change value <0.01Ω
Email
asia1100@163.com